Quantum Secular Labs / Blog / Advisories
CVE-2026-10520: Ivanti Sentry OS Command Injection Vulnerability
CVE-2026-10520 is rated critical with a CVSS v3.1 base score of 10.0 and affects Ivanti Sentry. Per its scoring, it can be exploited over the network, without authentication, without any user interaction. The scored impact on confidentiality, integrity and availability is the highest available. CISA added it to its Known Exploited Vulnerabilities catalog on 2026-06-11, which means exploitation in the wild has been observed.
Vulnerability description
An OS Command Injection vulnerability in Ivanti Sentry before the R10.5.2, R10.6.2 and R10.7.1 versions allows a remote unauthenticated user to achieve root-level remote code execution
Severity breakdown
CVSS v3.1 10.0: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
- Attack vector: Network. Exploitable remotely over the network, with no need for local or physical access.
- Attack complexity: Low. No special conditions; the attack can be repeated reliably.
- Privileges required: None. No account or prior access is needed.
- User interaction: None. No action from any user is needed.
- Scope: Changed. Impact reaches beyond the vulnerable component to other resources.
- Confidentiality impact: High. Total loss of confidentiality; sensitive data can be fully disclosed.
- Integrity impact: High. Total loss of integrity; data or system state can be fully modified.
- Availability impact: High. Total loss of availability; the component can be shut down.
Underlying weakness
CWE-78: Improper Neutralization of Special Elements used in an OS Command
The product constructs all or part of an OS command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended OS command before it is sent to a downstream component.
Affected products
- Ivanti Standalone Sentry: before 10.5.2; from 10.6.0 before 10.6.2; 10.7.0