CVE-2021-22681: Rockwell Multiple Products Insufficient Protected Credentials Vulnerability

CVE-2021-22681 is rated critical with a CVSS v3.1 base score of 9.8 and affects Rockwell Multiple Products, along with 1 other product in NVD’s configuration data. Per its scoring, it can be exploited over the network, without authentication, without any user interaction. The scored impact on confidentiality, integrity and availability is the highest available. CISA added it to its Known Exploited Vulnerabilities catalog on 2026-03-05, which means exploitation in the wild has been observed.

Vulnerability description

Rockwell Automation Studio 5000 Logix Designer Versions 21 and later, and RSLogix 5000 Versions 16 through 20 use a key to verify Logix controllers are communicating with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800. Rockwell Automation Studio 5000 Logix Designer Versions 21 and later and RSLogix 5000: Versions 16 through 20 are vulnerable because an unauthenticated attacker could bypass this verification mechanism and authenticate with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800.

Severity breakdown

CVSS v3.1 9.8: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

  • Attack vector: Network. Exploitable remotely over the network, with no need for local or physical access.
  • Attack complexity: Low. No special conditions; the attack can be repeated reliably.
  • Privileges required: None. No account or prior access is needed.
  • User interaction: None. No action from any user is needed.
  • Scope: Unchanged. Impact stays within the vulnerable component.
  • Confidentiality impact: High. Total loss of confidentiality; sensitive data can be fully disclosed.
  • Integrity impact: High. Total loss of integrity; data or system state can be fully modified.
  • Availability impact: High. Total loss of availability; the component can be shut down.

Underlying weakness

CWE-522: Insufficiently Protected Credentials

The product transmits or stores authentication credentials, but it uses an insecure method that is susceptible to unauthorized interception and/or retrieval.

Affected products

  • Rockwellautomation Rslogix 5000: from 16 up to and including 20
  • Rockwellautomation Studio 5000 Logix Designer: from 21.0
  • Rockwellautomation Factorytalk Services Platform: from 2.10