Quantum Secular Labs / Blog / Advisories
CVE-2020-10987: Tenda AC1900 Router AC15 Model Remote Code Execution Vulnerability
CVE-2020-10987 is rated critical with a CVSS v3.1 base score of 9.8 and affects Tenda AC1900 Router AC15 Model, along with 1 other product in NVD’s configuration data. Per its scoring, it can be exploited over the network, without authentication, without any user interaction. The scored impact on confidentiality, integrity and availability is the highest available. CISA added it to its Known Exploited Vulnerabilities catalog on 2021-11-03, which means exploitation in the wild has been observed.
Vulnerability description
The goform/setUsbUnload endpoint of Tenda AC15 AC1900 version 15.03.05.19 allows remote attackers to execute arbitrary system commands via the deviceName POST parameter.
Severity breakdown
CVSS v3.1 9.8: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Attack vector: Network. Exploitable remotely over the network, with no need for local or physical access.
- Attack complexity: Low. No special conditions; the attack can be repeated reliably.
- Privileges required: None. No account or prior access is needed.
- User interaction: None. No action from any user is needed.
- Scope: Unchanged. Impact stays within the vulnerable component.
- Confidentiality impact: High. Total loss of confidentiality; sensitive data can be fully disclosed.
- Integrity impact: High. Total loss of integrity; data or system state can be fully modified.
- Availability impact: High. Total loss of availability; the component can be shut down.
Underlying weakness
CWE-78: Improper Neutralization of Special Elements used in an OS Command
The product constructs all or part of an OS command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended OS command before it is sent to a downstream component.
Affected products
- Tenda Ac15 Firmware: 15.03.05.19