Quantum Secular Labs / Blog / Advisories

CVE-2018-7237: A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to…

CVE-2018-7237 is rated critical with a CVSS v3.1 base score of 9.1 and NVD lists 20 affected products, including Schneider Electric Mps110 1 Firmware. Per its scoring, it can be exploited over the network, without authentication, without any user interaction.

Vulnerability description

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow a remote attacker to delete arbitrary system file due to lack of validation of the /login/bin/set_param to the file name with the value of 'system.delete.sd_file'

Severity breakdown

CVSS v3.1 9.1: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H

  • Attack vector: Network. Exploitable remotely over the network, with no need for local or physical access.
  • Attack complexity: Low. No special conditions; the attack can be repeated reliably.
  • Privileges required: None. No account or prior access is needed.
  • User interaction: None. No action from any user is needed.
  • Scope: Unchanged. Impact stays within the vulnerable component.
  • Confidentiality impact: None. No loss of confidentiality.
  • Integrity impact: High. Total loss of integrity; data or system state can be fully modified.
  • Availability impact: High. Total loss of availability; the component can be shut down.

Underlying weakness

CWE-20: Improper Input Validation

The product receives input or data, but it does not validate or incorrectly validates that the input has the properties that are required to process the data safely and correctly.

Affected products

  • Schneider Electric Mps110 1 Firmware: before 3.29.67
  • Schneider Electric Imps110 1er Firmware: before 3.29.67
  • Schneider Electric Ibps110 1er Firmware: before 3.29.67
  • Schneider Electric Imp1110 1 Firmware: before 3.29.67
  • Schneider Electric Imp1110 1e Firmware: before 3.29.67
  • Schneider Electric Imp1110 1er Firmware: before 3.29.67
  • Schneider Electric Ibp1110 1er Firmware: before 3.29.67
  • Schneider Electric Imp219 1 Firmware: before 3.29.67
  • Schneider Electric Imp219 1e Firmware: before 3.29.67
  • Schneider Electric Imp219 1er Firmware: before 3.29.67
  • Schneider Electric Ibp219 1er Firmware: before 3.29.67
  • Schneider Electric Imp319 1 Firmware: before 3.29.67
  • Schneider Electric Imp319 1e Firmware: before 3.29.67
  • Schneider Electric Ibp319 1er Firmware: before 3.29.67
  • Schneider Electric Imp519 1 Firmware: before 3.29.67

References