Quantum Secular Labs / Blog / Advisories

CVE-2018-25237: Hirschmann HiSecOS devices versions prior to 05.3.03 contain a buffer overflow vulnerability in the HTTPS…

CVE-2018-25237 is rated critical with a CVSS v3.1 base score of 9.8. Per its scoring, it can be exploited over the network, without authentication, without any user interaction. The scored impact on confidentiality, integrity and availability is the highest available.

Vulnerability description

Hirschmann HiSecOS devices versions prior to 05.3.03 contain a buffer overflow vulnerability in the HTTPS login interface when RADIUS authentication is enabled that allows remote attackers to crash the device or execute arbitrary code by submitting a password longer than 128 characters. Attackers can exploit improper bounds checking in password handling to overflow a fixed-size buffer and achieve denial of service or remote code execution.

Severity breakdown

CVSS v3.1 9.8: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

  • Attack vector: Network. Exploitable remotely over the network, with no need for local or physical access.
  • Attack complexity: Low. No special conditions; the attack can be repeated reliably.
  • Privileges required: None. No account or prior access is needed.
  • User interaction: None. No action from any user is needed.
  • Scope: Unchanged. Impact stays within the vulnerable component.
  • Confidentiality impact: High. Total loss of confidentiality; sensitive data can be fully disclosed.
  • Integrity impact: High. Total loss of integrity; data or system state can be fully modified.
  • Availability impact: High. Total loss of availability; the component can be shut down.

Underlying weakness

CWE-120: Buffer Copy without Checking Size of Input

The product copies an input buffer to an output buffer without verifying that the size of the input buffer is less than the size of the output buffer.

Affected products

    References