Quantum Secular Labs / Blog / Advisories

CVE-2018-19064: An issue was discovered on Foscam C2 devices with System Firmware 1.11.1.8 and Application Firmware…

CVE-2018-19064 is rated critical with a CVSS v3.0 base score of 9.8 and NVD lists 4 affected products, including Opticam I5 Application Firmware. Per its scoring, it can be exploited over the network, without authentication, without any user interaction. The scored impact on confidentiality, integrity and availability is the highest available.

Vulnerability description

An issue was discovered on Foscam C2 devices with System Firmware 1.11.1.8 and Application Firmware 2.72.1.32, and Opticam i5 devices with System Firmware 1.5.2.11 and Application Firmware 2.21.1.128. The ftpuser1 account has a blank password, which cannot be changed.

Severity breakdown

CVSS v3.0 9.8: CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

  • Attack vector: Network. Exploitable remotely over the network, with no need for local or physical access.
  • Attack complexity: Low. No special conditions; the attack can be repeated reliably.
  • Privileges required: None. No account or prior access is needed.
  • User interaction: None. No action from any user is needed.
  • Scope: Unchanged. Impact stays within the vulnerable component.
  • Confidentiality impact: High. Total loss of confidentiality; sensitive data can be fully disclosed.
  • Integrity impact: High. Total loss of integrity; data or system state can be fully modified.
  • Availability impact: High. Total loss of availability; the component can be shut down.

Underlying weakness

CWE-521: Weak Password Requirements

The product does not require that users should have strong passwords.

Affected products

  • Opticam I5 Application Firmware: 2.21.1.128
  • Opticam I5 System Firmware: 1.5.2.11
  • Foscam C2 Application Firmware: 2.72.1.32
  • Foscam C2 System Firmware: 1.11.1.8

References