Quantum Secular Labs / Blog / Advisories

CVE-2018-16618: Vtech Storio Max Firmware: Command injection

CVE-2018-16618 is rated critical with a CVSS v3.0 base score of 9.8 and NVD lists Vtech Storio Max Firmware as the affected product. Per its scoring, it can be exploited over the network, without authentication, without any user interaction. The scored impact on confidentiality, integrity and availability is the highest available.

Vulnerability description

VTech Storio Max before 56.D3JM6 allows remote command execution via shell metacharacters in an Android activity name. It exposes the storeintenttranslate.x service on port 1668 listening for requests on localhost. Requests submitted to this service are checked for a string of random characters followed by the name of an Android activity to start. Activities are started by inserting their name into a string that is executed in a shell command. By inserting metacharacters this can be exploited to run arbitrary commands as root. The requests also match those of the HTTP protocol and can be triggered on any web page rendered on the device by requesting resources stored at an http://127.0.0.1:1668/ URI, as demonstrated by the http://127.0.0.1:1668/dacdb70556479813fab2d92896596eef?';{ping,example.org}' URL.

Severity breakdown

CVSS v3.0 9.8: CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

  • Attack vector: Network. Exploitable remotely over the network, with no need for local or physical access.
  • Attack complexity: Low. No special conditions; the attack can be repeated reliably.
  • Privileges required: None. No account or prior access is needed.
  • User interaction: None. No action from any user is needed.
  • Scope: Unchanged. Impact stays within the vulnerable component.
  • Confidentiality impact: High. Total loss of confidentiality; sensitive data can be fully disclosed.
  • Integrity impact: High. Total loss of integrity; data or system state can be fully modified.
  • Availability impact: High. Total loss of availability; the component can be shut down.

Underlying weakness

CWE-78: Improper Neutralization of Special Elements used in an OS Command

The product constructs all or part of an OS command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended OS command before it is sent to a downstream component.

Affected products

  • Vtech Storio Max Firmware: before 56.d3jm6

References