CVE-2018-11426: Moxa Oncell G3150 Hspa Firmware: Authentication bypass
CVE-2018-11426 is rated critical with a CVSS v3.0 base score of 9.8 and NVD lists 2 affected products, including Moxa Oncell G3150 Hspa Firmware. Per its scoring, it can be exploited over the network, without authentication, without any user interaction. The scored impact on confidentiality, integrity and availability is the highest available.
Vulnerability description
A weak Cookie parameter is used in the web application of Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. An attacker can brute force parameters required to bypass authentication and access the web interface to use all its functions except for password change.
Severity breakdown
CVSS v3.0 9.8: CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Attack vector: Network. Exploitable remotely over the network, with no need for local or physical access.
- Attack complexity: Low. No special conditions; the attack can be repeated reliably.
- Privileges required: None. No account or prior access is needed.
- User interaction: None. No action from any user is needed.
- Scope: Unchanged. Impact stays within the vulnerable component.
- Confidentiality impact: High. Total loss of confidentiality; sensitive data can be fully disclosed.
- Integrity impact: High. Total loss of integrity; data or system state can be fully modified.
- Availability impact: High. Total loss of availability; the component can be shut down.
Underlying weakness
CWE-287: Improper Authentication
When an actor claims to have a given identity, the product does not prove or insufficiently proves that the claim is correct.
Affected products
- Moxa Oncell G3150 Hspa Firmware: up to and including 1.4
- Moxa Oncell G3150 Hspa T Firmware: up to and including 1.4