Quantum Secular Labs / Blog / Advisories
CVE-2017-13771: Lexmark Scan To Network: Information disclosure
CVE-2017-13771 is rated critical with a CVSS v3.0 base score of 9.8 and affects Lexmark Scan To Network. Per its scoring, it can be exploited over the network, without authentication, without any user interaction. The scored impact on confidentiality, integrity and availability is the highest available.
Vulnerability description
Lexmark Scan To Network (SNF) 3.2.9 and earlier stores network configuration credentials in plaintext and transmits them in requests, which allows remote attackers to obtain sensitive information via requests to (1) cgi-bin/direct/printer/prtappauth/apps/snfDestServlet or (2) cgi-bin/direct/printer/prtappauth/apps/ImportExportServlet.
Severity breakdown
CVSS v3.0 9.8: CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Attack vector: Network. Exploitable remotely over the network, with no need for local or physical access.
- Attack complexity: Low. No special conditions; the attack can be repeated reliably.
- Privileges required: None. No account or prior access is needed.
- User interaction: None. No action from any user is needed.
- Scope: Unchanged. Impact stays within the vulnerable component.
- Confidentiality impact: High. Total loss of confidentiality; sensitive data can be fully disclosed.
- Integrity impact: High. Total loss of integrity; data or system state can be fully modified.
- Availability impact: High. Total loss of availability; the component can be shut down.
Underlying weakness
CWE-522: Insufficiently Protected Credentials
The product transmits or stores authentication credentials, but it uses an insecure method that is susceptible to unauthorized interception and/or retrieval.
Affected products
- Lexmark Scan To Network: up to and including 3.2.9