Quantum Secular Labs / Blog / Advisories
CVE-2001-0133: The web administration interface for Interscan VirusWall 3.6.x and earlier does not use encryption, which…
CVE-2001-0133 has a CVSS v2 base score of 10.0 (the maximum on that scale) and affects Trend Micro Interscan Viruswall. Per its scoring, it can be exploited over the network, without authentication. The scored impact on confidentiality, integrity and availability is the highest available.
Vulnerability description
The web administration interface for Interscan VirusWall 3.6.x and earlier does not use encryption, which could allow remote attackers to obtain the administrator password to sniff the administrator password via the setpasswd.cgi program or other HTTP GET requests that contain base64 encoded usernames and passwords.
Severity breakdown
CVSS v2.0 10.0: AV:N/AC:L/Au:N/C:C/I:C/A:C
- Access vector: Network. Exploitable remotely over the network.
- Access complexity: Low. No special conditions are required.
- Authentication: None. No authentication is needed.
- Confidentiality impact: Complete. Total information disclosure.
- Integrity impact: Complete. Total loss of integrity.
- Availability impact: Complete. Total shutdown of the component.
Affected products
- Trend Micro Interscan Viruswall: up to and including 3.6; 3.0.1